Microsoft-Windows-FailoverClustering-ClusDisk-Diagnostic

EventTitleChannelSampleRule
1Event ID 1OperationalNN
1PhysicalDrive.SystemNN

Event ID 1

#
Channel
Operational

Fields #

NameDescription
Status HexInt32NTSTATUS reference
Device UInt32
VendorId AnsiString
ProductId AnsiString
SerialNumber AnsiString

Event ID 1: PhysicalDrive.

#
Channel
System

Message #

PhysicalDrive%2 (Disk Vendor Id '%3' Product Id '%4' Serial Number '%5') has persistent registration keys that do not belong to current active cluster membership. This could be due to an issue in drive firmware or because node that has pool resource has no connectivity to the disk to preempt unexpected registration keys. This may prevent clustered virtual disks from coming online on this node. Status %1

Fields #

NameDescription
Status HexInt32NTSTATUS reference
Device UInt32
VendorId AnsiString
ProductId AnsiString
SerialNumber AnsiString

Provenance

ETW provider GUID 7fef367f-e76c-4592-9912-e12b36a99780

Defined in ClusDisk.sys, the binary that emits these events.