Microsoft-Windows-HealthCenter
47 events across 2 channels
Event ID 1: The check provider CLSID has been disabled.
#Event ID 2: Icon message received: Icon_message_received.
#Event ID 3: Notification already exists: Notification_already_exists.
#Event ID 4: An event specifying unknown check EventID (version EventVeresion) was found in the channel ChannelName.
#Event ID 5: An event specifying unknown state StateID for check with canonical name CanonicalName was found.
#Event ID 6: Failed to set state (StateID) for check with canonical name CanonicalName: HRESULT = HRESULT.
#Event ID 7: Worker thread failure during initialization: HRESULT=HRESULT.
#Event ID 8: Failed to set icon state when adding new notification: HRESULT=HRESULT.
#Event ID 9: Icon processing of new notification failed: HRESULT=HRESULT.
#Event ID 10: Icon processing of notification removal failed: HRESULT=HRESULT.
#Event ID 11: Cache read for check provider CanonicalName: HRESULT=HRESULT.
#Event ID 12: Cache written for check provider CanonicalName: HRESULT=HRESULT.
#Event ID 13: Failed to process new crimson event from channel ChannelName: HRESULT=HRESULT.
#Event ID 14: Failed to set bookmark for channel ChannelName: HRESULT=HRESULT.
#Event ID 15: Error event in channel ChannelName.
#Event ID 16: Failed to process an existing event for channel ChannelName: HRESULT=HRESULT.
#Event ID 17: Failed failed while reading existing events for channel ChannelName: HRESULT=HRESULT.
#Event ID 18: Failed to resolve InputString: HRESULT=HRESULT.
#Event ID 19: Failed to load settings for check with canonical name CanonicalName: HRESULT=HRESULT.
#Event ID 20: Added notification with canonical name CanonicalName.
#Event ID 21: Removed notification with canonical name CanonicalName.
#Event ID 100: HealthCenter_StringExpansionStart
#Event ID 101: HealthCenter_StringExpansionStop
#Event ID 102: HealthCenter_StateChangeStart
#Event ID 103: HealthCenter_StateChangeStop
#Event ID 104: HealthCenter_LoadFromCacheStart
#Event ID 105: HealthCenter_LoadFromCacheStop
#Event ID 106: HealthCenter_SaveToCacheStart
#Event ID 107: HealthCenter_SaveToCacheStop
#Event ID 108: HealthCenter_StartupStart
#Event ID 109: HealthCenter_StartupStop
#Event ID 110: HealthCenter_ShutdownStart
#Event ID 111: HealthCenter_ShutdownStop
#Event ID 112: HealthCenter_IconBalloonStart
#Event ID 113: HealthCenter_IconBalloonStop
#Event ID 114: HealthCenter_IconToolTipStart
#Event ID 115: HealthCenter_IconToolTipStop
#Event ID 116: HealthCenter_IconFlyoutStart
#Event ID 117: HealthCenter_IconFlyoutStop
#Event ID 120: HealthCenter_IconProcessNotificationStart
#Event ID 121: HealthCenter_IconProcessNotificationStop
#Event ID 124: HealthCenter_CPLLaunch
#Event ID 1000: Perftrack_HealthCenter_IconInitializedStart
#Event ID 1001: Perftrack_HealthCenter_IconInitializedStop
#Event ID 1002: Perftrack_HealthCenter_OpenUsingIconFlyoutStop
#Provenance
Where this provider's schema came from, and which Windows build it was observed on. Windows can change a provider's event schema between builds, so use this to judge whether it matches the build you collect from.
ETW provider GUID 588c5c5a-ffc5-44a2-9a7f-d5e8dbe6efd7
Defined in actioncenter.dll, which carries the event manifest.
Observed on:
- WS2022-20348.4893, schema read from the registered manifest, binary version 10.0.20348.1, captured 2026-06-02
- Win11-26200.6584, schema read from the registered manifest, binary version 10.0.26100.1, captured 2026-06-02