Microsoft-Windows-Hyper-V-SynthNic
118 events across 3 channels
Event ID 1: [VMID VmId]
#Fields #
| Name | Description |
|---|---|
TraceData UnicodeString | |
VmName UnicodeString | |
VmId UnicodeString | |
StackFrameCount UInt32 | |
StackFrame Pointer | |
ModuleCount UInt32 | |
Module Int32 |
Event ID 1: [VMID VmId] TraceData.
#Event ID 2: [VMID VmId]
#Fields #
| Name | Description |
|---|---|
TraceData UnicodeString | |
VmName UnicodeString | |
VmId UnicodeString | |
StackFrameCount UInt32 | |
StackFrame Pointer | |
ModuleCount UInt32 | |
Module Int32 |
Event ID 2: [VMID VmId] TraceData.
#Event ID 3: [VMID VmId]
#Fields #
| Name | Description |
|---|---|
TraceData UnicodeString | |
VmName UnicodeString | |
VmId UnicodeString | |
StackFrameCount UInt32 | |
StackFrame Pointer | |
ModuleCount UInt32 | |
Module Int32 |
Event ID 3: [VMID VmId] TraceData.
#Event ID 4: [VMID VmId]
#Fields #
| Name | Description |
|---|---|
TraceData UnicodeString | |
VmName UnicodeString | |
VmId UnicodeString | |
StackFrameCount UInt32 | |
StackFrame Pointer | |
ModuleCount UInt32 | |
Module Int32 |
Event ID 4: [VMID VmId] TraceData.
#Event ID 12560: 'VmName' Static MAC address MacAddress for "NicName" (NicGuid) is invalid
#Description
'VmName' Static MAC address MacAddress for "NicName" (NicGuid) is invalid.
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
MacAddress UnicodeString |
Event ID 12560: 'VmName' Static MAC address MacAddress for "NicName" (NicGuid) is invalid.
#Event ID 12562: 'VmName' Static MAC address MacAddress for "NicName" (NicGuid) conflicts with another adapter
#Description
'VmName' Static MAC address MacAddress for "NicName" (NicGuid) conflicts with another adapter.
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
MacAddress UnicodeString |
Event ID 12562: 'VmName' Static MAC address MacAddress for "NicName" (NicGuid) conflicts with another adapter.
#Event ID 12564: 'VmName' No available MAC address for "NicName"
#Description
'VmName' No available MAC address for "NicName".
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12564: 'VmName' No available MAC address for "NicName".
#Event ID 12572: 'VmName' Dynamic MAC address for "NicName" (NicGuid) was not assigned
#Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
MacAddress UnicodeString |
Event ID 12572: '.
#Event ID 12580: 'VmName' Dynamic MAC address MacAddress for NicName (NicGuid) is invalid
#Description
'VmName' Dynamic MAC address MacAddress for NicName (NicGuid) is invalid.
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
MacAddress UnicodeString |
Event ID 12580: 'VmName' Dynamic MAC address MacAddress for NicName (NicGuid) is invalid.
#Event ID 12581: Dynamic MAC address MacAddress for NicName (NicGuid) is invalid
#Description
Dynamic MAC address for () is invalid.
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
MacAddress UnicodeString |
Event ID 12581: Dynamic MAC address MacAddress for NicName (NicGuid) is invalid.
#Event ID 12582: 'VmName' NicName (NicGuid) started successfully
#Description
'VmName' NicName (NicGuid) started successfully. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12582: 'VmNicNoAvailableMac.VmName' VmNicNoAvailableMac.NicName (VmNicNoAvailableMac.NicGuid) started successfully.
#Description
'VmNicNoAvailableMac.VmName' VmNicNoAvailableMac.NicName (VmNicNoAvailableMac.NicGuid) started successfully. (Virtual Machine ID VmNicNoAvailableMac.VmId).
Message #
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Example Event #
{
"system": {
"provider": "Microsoft-Windows-Hyper-V-SynthNic",
"guid": "C29C4FB7-B60E-4FFF-9AF9-CF21F9B09A34",
"event_source_name": "",
"event_id": 12582,
"version": 0,
"level": 4,
"task": 0,
"opcode": 0,
"keywords": 9223372036854775808,
"time_created": "2026-03-11T06:32:02.482486+00:00",
"event_record_id": 12,
"correlation": {
"ActivityID": "F0567312-CB60-43FE-9013-B91DE669B588"
},
"execution": {
"process_id": 9436,
"thread_id": 10020
},
"channel": "Microsoft-Windows-Hyper-V-Worker-Admin",
"computer": "LAB-WIN11",
"security": {
"user_id": "S-1-5-83-1-698845485-1245677379-4261864325-3027728797"
}
},
"user_data": {
"VmNicNoAvailableMac": {
"VmName": "29A7892D-8743-4A3F-85E3-06FE9D7977B4",
"VmId": "29A7892D-8743-4A3F-85E3-06FE9D7977B4",
"NicGuid": "AD2366C4-0BE2-4636-8124-F3BDDFD27E15",
"NicName": null
}
},
"message": ""
}
Event ID 12583: 'VmName' NicName (NicGuid) started successfully
#Description
'VmName' NicName (NicGuid) started successfully. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12583: 'VmName' NicName (NicGuid) started successfully.
#Event ID 12584: 'VmName' NicName (NicGuid) allocated a virtual function
#Description
'VmName' NicName (NicGuid) allocated a virtual function. (Virtual Function ID VfId LUID PfLuid Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString |
Event ID 12584: 'VmName' NicName (NicGuid) allocated a virtual function.
#Event ID 12585: 'VmName' NicName (NicGuid) failed to allocate a virtual function: ErrorCodeString (ErrorCode): IOV networking might be incompatible with other configured networking features
#Description
'VmName' NicName (NicGuid) failed to allocate a virtual function: ErrorCodeString (ErrorCode): IOV networking might be incompatible with other configured networking features. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString | |
ErrorCodeString UnicodeString | |
ErrorCode UnicodeString |
Event ID 12585: 'VmName' NicName (NicGuid) failed to allocate a virtual function: ErrorCodeString (ErrorCode): IOV networking might be incompatible with other configured networking features.
#Description
'VmName' NicName (NicGuid) failed to allocate a virtual function: ErrorCodeString (ErrorCode): IOV networking might be incompatible with other configured networking features. (Virtual Machine ID VmId).
Message #
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString | |
ErrorCodeString UnicodeString | |
ErrorCode UnicodeString |
Event ID 12586: 'VmName' NicName (NicGuid) freed a virtual function
#Description
'VmName' NicName (NicGuid) freed a virtual function. (Virtual Function ID VfId Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString |
Event ID 12586: 'VmName' NicName (NicGuid) freed a virtual function.
#Event ID 12587: 'VmName' NicName (NicGuid) failed to free a virtual function: ErrorCodeString (ErrorCode) (Virtual Function ID VfId Virtual Machine ID VmId)
#Description
'VmName' NicName (NicGuid) failed to free a virtual function: ErrorCodeString (ErrorCode) (Virtual Function ID VfId Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString | |
ErrorCodeString UnicodeString | |
ErrorCode UnicodeString |
Event ID 12587: 'VmName' NicName (NicGuid) failed to free a virtual function: ErrorCodeString (ErrorCode) (Virtual Function ID VfId Virtual Machine ID VmId).
#Description
'VmName' NicName (NicGuid) failed to free a virtual function: ErrorCodeString (ErrorCode) (Virtual Function ID VfId Virtual Machine ID VmId).
Message #
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString | |
ErrorCodeString UnicodeString | |
ErrorCode UnicodeString |
Event ID 12588: 'VmName' NicName (NicGuid) assigned a virtual function
#Description
'VmName' NicName (NicGuid) assigned a virtual function. (Virtual Function ID VfId LUID PfLuid) (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString |
Event ID 12588: 'VmName' NicName (NicGuid) assigned a virtual function.
#Event ID 12589: 'VmName' NicName (NicGuid) failed to assign a virtual function: ErrorCodeString (ErrorCode) (Virtual Function ID VfId LUID PfLuid) (Virtual Machine ID VmId)
#Description
'VmName' NicName (NicGuid) failed to assign a virtual function: ErrorCodeString (ErrorCode) (Virtual Function ID VfId LUID PfLuid) (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString | |
ErrorCodeString UnicodeString | |
ErrorCode UnicodeString |
Event ID 12589: 'VmName' NicName (NicGuid) failed to assign a virtual function: ErrorCodeString (ErrorCode) (Virtual Function ID VfId LUID PfLuid) (Virtual Machine ID VmId).
#Description
'VmName' NicName (NicGuid) failed to assign a virtual function: ErrorCodeString (ErrorCode) (Virtual Function ID VfId LUID PfLuid) (Virtual Machine ID VmId).
Message #
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString | |
ErrorCodeString UnicodeString | |
ErrorCode UnicodeString |
Event ID 12590: 'VmName' NicName (NicGuid) unassigned a virtual function
#Description
'VmName' NicName (NicGuid) unassigned a virtual function. (Virtual Function ID VfId Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString |
Event ID 12590: 'VmName' NicName (NicGuid) unassigned a virtual function.
#Event ID 12597: 'VmName' NicName (NicGuid) Connected to virtual network
#Description
'VmName' NicName (NicGuid) Connected to virtual network. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12597: 'VmNicNoAvailableMac.VmName' VmNicNoAvailableMac.NicName (VmNicNoAvailableMac.NicGuid) Connected to virtual network.
#Description
'VmNicNoAvailableMac.VmName' VmNicNoAvailableMac.NicName (VmNicNoAvailableMac.NicGuid) Connected to virtual network. (Virtual Machine ID VmNicNoAvailableMac.VmId).
Message #
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Example Event #
{
"system": {
"provider": "Microsoft-Windows-Hyper-V-SynthNic",
"guid": "C29C4FB7-B60E-4FFF-9AF9-CF21F9B09A34",
"event_source_name": "",
"event_id": 12597,
"version": 0,
"level": 4,
"task": 0,
"opcode": 0,
"keywords": 9223372036854775808,
"time_created": "2026-03-11T06:32:02.482454+00:00",
"event_record_id": 11,
"correlation": {
"ActivityID": "F0567312-CB60-43FE-9013-B91DE669B588"
},
"execution": {
"process_id": 9436,
"thread_id": 10020
},
"channel": "Microsoft-Windows-Hyper-V-Worker-Admin",
"computer": "LAB-WIN11",
"security": {
"user_id": "S-1-5-83-1-698845485-1245677379-4261864325-3027728797"
}
},
"user_data": {
"VmNicNoAvailableMac": {
"VmName": "29A7892D-8743-4A3F-85E3-06FE9D7977B4",
"VmId": "29A7892D-8743-4A3F-85E3-06FE9D7977B4",
"NicGuid": "29A7892D-8743-4A3F-85E3-06FE9D7977B4--AD2366C4-0BE2-4636-8124-F3BDDFD27E15",
"NicName": null
}
},
"message": ""
}
Event ID 12598: 'VmName' NicName (NicGuid) Disconnected from virtual network
#Description
'VmName' NicName (NicGuid) Disconnected from virtual network. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12598: 'VmName' NicName (NicGuid) Disconnected from virtual network.
#Event ID 12603: 'VmName' NicName (NicGuid) Smart Paging now inactive
#Description
'VmName' NicName (NicGuid) Smart Paging now inactive. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12603: 'VmName' NicName (NicGuid) Smart Paging now inactive.
#Event ID 12604: 'VmName' NicName (NicGuid) Smart Paging now active
#Description
'VmName' NicName (NicGuid) Smart Paging now active. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12604: 'VmName' NicName (NicGuid) Smart Paging now active.
#Event ID 12605: 'VmName' NicName (NicGuid) is configured to use SR-IOV but that capability is not supported on this version of Windows
#Description
'VmName' NicName (NicGuid) is configured to use SR-IOV but that capability is not supported on this version of Windows. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12605: 'VmName' NicName (NicGuid) is configured to use SR-IOV but that capability is not supported on this version of Windows.
#Event ID 12606: 'VmName' NicName (NicGuid) is configured to use SR-IOV but this system does not have an IOMMU or the IOMMU is currently disabled
#Description
'VmName' NicName (NicGuid) is configured to use SR-IOV but this system does not have an IOMMU or the IOMMU is currently disabled. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12606: 'VmName' NicName (NicGuid) is configured to use SR-IOV but this system does not have an IOMMU or the IOMMU is currently disabled.
#Event ID 12607: 'VmName' NicName (NicGuid) is configured to use SR-IOV but that capability is disabled by policy on this machine
#Description
'VmName' NicName (NicGuid) is configured to use SR-IOV but that capability is disabled by policy on this machine. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12607: 'VmName' NicName (NicGuid) is configured to use SR-IOV but that capability is disabled by policy on this machine.
#Event ID 12608: 'VmName' NicName (NicGuid) failed to allocate a virtual function because the switch to which the virtual NIC is connected to is not in SR-IOV mode
#Description
'VmName' NicName (NicGuid) failed to allocate a virtual function because the switch to which the virtual NIC is connected to is not in SR-IOV mode. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12608: 'VmName' NicName (NicGuid) failed to allocate a virtual function because the switch to which the virtual NIC is connected to is not in SR-IOV mode.
#Event ID 12609: 'VmName' NicName (NicGuid) failed to allocate a virtual function because the physical NIC does not support SR-IOV
#Description
'VmName' NicName (NicGuid) failed to allocate a virtual function because the physical NIC does not support SR-IOV. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12609: 'VmName' NicName (NicGuid) failed to allocate a virtual function because the physical NIC does not support SR-IOV.
#Event ID 12612: 'VmName' NicName (NicGuid) unassigning a virtual function because of an invalid DMA operation by the guest operating system
#Description
'VmName' NicName (NicGuid) unassigning a virtual function because of an invalid DMA operation by the guest operating system. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12612: 'VmName' NicName (NicGuid) unassigning a virtual function because of an invalid DMA operation by the guest operating system.
#Event ID 12613: 'VmName' NicName (NicGuid) The number of queue pairs allocated to the virtual function (VfId) were less than requested (PfLuid)
#Description
'VmName' NicName (NicGuid) The number of queue pairs allocated to the virtual function (VfId) were less than requested (PfLuid). (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString |
Event ID 12613: 'VmName' NicName (NicGuid) The number of queue pairs allocated to the virtual function (VfId) were less than requested (PfLuid).
#Description
'VmName' NicName (NicGuid) The number of queue pairs allocated to the virtual function (VfId) were less than requested (PfLuid). (Virtual Machine ID VmId).
Message #
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString |
Event ID 12614: 'VmName' NicName (NicGuid) The number of queue pairs to be allocated (VfId) were limited because of the number of virtual processors (PfLuid) for the VM
#Description
'VmName' NicName (NicGuid) The number of queue pairs to be allocated (VfId) were limited because of the number of virtual processors (PfLuid) for the VM. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString |
Event ID 12614: 'VmName' NicName (NicGuid) The number of queue pairs to be allocated (VfId) were limited because of the number of virtual processors (PfLuid) for the VM.
#Description
'VmName' NicName (NicGuid) The number of queue pairs to be allocated (VfId) were limited because of the number of virtual processors (PfLuid) for the VM. (Virtual Machine ID VmId).
Message #
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString |
Event ID 12615: The device naming setting only applies to synthetic network adapters on Generation 2 virtual machines with configuration version 6
#Description
The device naming setting only applies to synthetic network adapters on Generation 2 virtual machines with configuration version 6.2 or above. (Virtual machine ID ).
Fields #
| Name | Description |
|---|---|
VmId UnicodeString |
Event ID 12615: The device naming setting only applies to synthetic network adapters on Generation 2 virtual machines with configuration version 6.
#Event ID 12670: 'VmName' failed to allocate resources while connecting to a virtual network: ErrorCodeString (ErrorCode) (Virtual Machine ID VmId)
#Description
'VmName' failed to allocate resources while connecting to a virtual network: ErrorCodeString (ErrorCode) (Virtual Machine ID VmId). The Ethernet switch may not exist.
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
String UnicodeString | |
ErrorCodeString UnicodeString | |
ErrorCode UnicodeString | |
Param1 UnicodeString | |
Param2 UnicodeString |
Event ID 12670: 'VmName' failed to allocate resources while connecting to a virtual network: ErrorCodeString (ErrorCode) (Virtual Machine ID VmId).
#Description
'VmName' failed to allocate resources while connecting to a virtual network: ErrorCodeString (ErrorCode) (Virtual Machine ID VmId). The Ethernet switch may not exist.
Message #
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
String UnicodeString | |
ErrorCodeString UnicodeString | |
ErrorCode UnicodeString | |
Param1 UnicodeString | |
Param2 UnicodeString |
Event ID 12671: Failed to allocate resources while connecting to a virtual network
#Description
Failed to allocate resources while connecting to a virtual network. The Ethernet switch may not exist.
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
String UnicodeString | |
ErrorCodeString UnicodeString | |
ErrorCode UnicodeString | |
Param1 UnicodeString | |
Param2 UnicodeString |
Event ID 12671: Failed to allocate resources while connecting to a virtual network.
#Event ID 12680: 'VmName' The VirtualSystemIdentifier VmId for "NicName" (NicGuid) conflicts with another adapter
#Description
'VmName' The VirtualSystemIdentifier VmId for "NicName" (NicGuid) conflicts with another adapter.
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12680: 'VmName' The VirtualSystemIdentifier VmId for "NicName" (NicGuid) conflicts with another adapter.
#Event ID 12692: Bytes sent or received by 'VmName' is larger than what can fit inside of a 64-bit integer
#Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
String UnicodeString | |
ErrorCodeString UnicodeString | |
ErrorCode UnicodeString | |
Param1 UnicodeString | |
Param2 UnicodeString |
Event ID 12692: Bytes sent or received by 'VmName' is larger than what can fit inside of a 64-bit integer.
#Event ID 12693: Bytes send or received is larger than what can fit inside of an unsigned 64-bit integer
#Description
Bytes send or received is larger than what can fit inside of an unsigned 64-bit integer.
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
String UnicodeString | |
ErrorCodeString UnicodeString | |
ErrorCode UnicodeString | |
Param1 UnicodeString | |
Param2 UnicodeString |
Event ID 12693: Bytes send or received is larger than what can fit inside of an unsigned 64-bit integer.
#Event ID 12694: 'VmName' NicName (NicGuid) Pause failed
#Description
'VmName' NicName (NicGuid) Pause failed. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12694: 'VmName' NicName (NicGuid) Pause failed.
#Event ID 12695: 'VmName' NicName (NicGuid) ShutDown failed
#Description
'VmName' NicName (NicGuid) ShutDown failed. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12695: 'VmName' NicName (NicGuid) ShutDown failed.
#Event ID 12696: 'VmName' NicName (NicGuid) VMPhu Zero start sequence failed
#Description
'VmName' NicName (NicGuid) VMPhu Zero start sequence failed. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12696: 'VmName' NicName (NicGuid) VMPhu Zero start sequence failed.
#Event ID 12697: 'VmName' NicName (NicGuid) VMPhu Zero start sequence succeeded
#Description
'VmName' NicName (NicGuid) VMPhu Zero start sequence succeeded. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12697: 'VmName' NicName (NicGuid) VMPhu Zero start sequence succeeded.
#Event ID 12698: 'VmName' NicName (NicGuid) Save failed
#Description
'VmName' NicName (NicGuid) Save failed. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12698: 'VmName' NicName (NicGuid) Save failed.
#Event ID 12699: 'VmName' NicName (NicGuid) PowerOn failed
#Description
'VmName' NicName (NicGuid) PowerOn failed. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12699: 'VmName' NicName (NicGuid) PowerOn failed.
#Event ID 12700: 'VmName' NicName (NicGuid) Restore failed
#Description
'VmName' NicName (NicGuid) Restore failed. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12700: 'VmName' NicName (NicGuid) Restore failed.
#Event ID 12701: 'VmName' NicName (NicGuid) Resume failed
#Description
'VmName' NicName (NicGuid) Resume failed. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12701: 'VmName' NicName (NicGuid) Resume failed.
#Event ID 12702: 'VmName' NicName (NicGuid) VMPhu Zero complete sequence failed
#Description
'VmName' NicName (NicGuid) VMPhu Zero complete sequence failed. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12702: 'VmName' NicName (NicGuid) VMPhu Zero complete sequence failed.
#Event ID 12703: 'VmName' NicName (NicGuid) VMPhu Zero complete sequence succeeded
#Description
'VmName' NicName (NicGuid) VMPhu Zero complete sequence succeeded. (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString |
Event ID 12703: 'VmName' NicName (NicGuid) VMPhu Zero complete sequence succeeded.
#Event ID 12704: 'VmName' NicName (NicGuid) successfully saved the keep alive virtual function
#Description
'VmName' NicName (NicGuid) successfully saved the keep alive virtual function. (Virtual Function ID VfId LUID PfLuid) (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString |
Event ID 12704: 'VmName' NicName (NicGuid) successfully saved the keep alive virtual function.
#Description
'VmName' NicName (NicGuid) successfully saved the keep alive virtual function. (Virtual Function ID VfId LUID PfLuid) (Virtual Machine ID VmId).
Message #
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString |
Event ID 12705: 'VmName' NicName (NicGuid) successfully assigned the keep alive virtual function
#Description
'VmName' NicName (NicGuid) successfully assigned the keep alive virtual function. (Virtual Function ID VfId LUID PfLuid) (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString |
Event ID 12705: 'VmName' NicName (NicGuid) successfully assigned the keep alive virtual function.
#Description
'VmName' NicName (NicGuid) successfully assigned the keep alive virtual function. (Virtual Function ID VfId LUID PfLuid) (Virtual Machine ID VmId).
Message #
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString |
Event ID 12706: 'VmName' NicName (NicGuid) failed to assign the keep alive virtual function: ErrorCodeString (ErrorCode) (Virtual Function ID VfId LUID PfLuid) (Virtual Machine ID VmId)
#Description
'VmName' NicName (NicGuid) failed to assign the keep alive virtual function: ErrorCodeString (ErrorCode) (Virtual Function ID VfId LUID PfLuid) (Virtual Machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString | |
ErrorCodeString UnicodeString | |
ErrorCode UnicodeString |
Event ID 12706: 'VmName' NicName (NicGuid) failed to assign the keep alive virtual function: ErrorCodeString (ErrorCode) (Virtual Function ID VfId LUID PfLuid) (Virtual Machine ID VmId).
#Description
'VmName' NicName (NicGuid) failed to assign the keep alive virtual function: ErrorCodeString (ErrorCode) (Virtual Function ID VfId LUID PfLuid) (Virtual Machine ID VmId).
Message #
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | |
VmId UnicodeString | |
NicGuid UnicodeString | |
NicName UnicodeString | |
VfId UnicodeString | |
PfLuid UnicodeString | |
ErrorCodeString UnicodeString | |
ErrorCode UnicodeString |
Event ID 25400: Started Allocating VF on Nic (Name: Parameter0)
#Description
Started Allocating VF on Nic (Name: ). (Virtual machine ID ).
Fields #
| Name | Description |
|---|---|
VmId UnicodeString | |
Parameter0 UnicodeString |
Event ID 25400: Started Allocating VF on Nic (Name: Parameter0).
#Event ID 25401: Finished Allocating VF (VFID: Parameter1) on Nic (Name: Parameter0), time Time s
#Description
Finished Allocating VF (VFID: ) on Nic (Name: ), time s. (Virtual machine ID ).
Fields #
| Name | Description |
|---|---|
VmId UnicodeString | |
Time UnicodeString | |
Parameter0 UnicodeString | |
Parameter1 UInt32 |
Event ID 25401: Finished Allocating VF (VFID: Parameter1) on Nic (Name: Parameter0), time Time s.
#Event ID 25402: Started Deallocating VF (VFID: Parameter1) on Nic (Name: Parameter0)
#Description
Started Deallocating VF (VFID: ) on Nic (Name: ). (Virtual machine ID ).
Fields #
| Name | Description |
|---|---|
VmId UnicodeString | |
Parameter0 UnicodeString | |
Parameter1 UInt32 |
Event ID 25402: Started Deallocating VF (VFID: Parameter1) on Nic (Name: Parameter0).
#Event ID 25403: Finished Deallocating VF (VFID: Parameter1) on Nic (Name: Parameter0), time Time s
#Description
Finished Deallocating VF (VFID: ) on Nic (Name: ), time s. (Virtual machine ID ).
Fields #
| Name | Description |
|---|---|
VmId UnicodeString | |
Time UnicodeString | |
Parameter0 UnicodeString | |
Parameter1 UInt32 |
Event ID 25403: Finished Deallocating VF (VFID: Parameter1) on Nic (Name: Parameter0), time Time s.
#Event ID 25410: Started Assigning VF (VFID: Parameter1) on Nic (Name: Parameter0)
#Description
Started Assigning VF (VFID: ) on Nic (Name: ). (Virtual machine ID ).
Fields #
| Name | Description |
|---|---|
VmId UnicodeString | |
Parameter0 UnicodeString | |
Parameter1 UInt32 |
Event ID 25410: Started Assigning VF (VFID: Parameter1) on Nic (Name: Parameter0).
#Event ID 25411: Finished Assigning VF (VFID: Parameter1) on Nic (Name: Parameter0), time Time s
#Description
Finished Assigning VF (VFID: ) on Nic (Name: ), time s. (Virtual machine ID ).
Fields #
| Name | Description |
|---|---|
VmId UnicodeString | |
Time UnicodeString | |
Parameter0 UnicodeString | |
Parameter1 UInt32 |
Event ID 25411: Finished Assigning VF (VFID: Parameter1) on Nic (Name: Parameter0), time Time s.
#Event ID 25412: Started Unassigning VF (VFID: Parameter1) on Nic (Name: Parameter0)
#Description
Started Unassigning VF (VFID: ) on Nic (Name: ). (Virtual machine ID ).
Fields #
| Name | Description |
|---|---|
VmId UnicodeString | |
Parameter0 UnicodeString | |
Parameter1 UInt32 |
Event ID 25412: Started Unassigning VF (VFID: Parameter1) on Nic (Name: Parameter0).
#Event ID 25413: Finished Unassigning VF (VFID: Parameter1) on Nic (Name: Parameter0), time Time s
#Description
Finished Unassigning VF (VFID: ) on Nic (Name: ), time s. (Virtual machine ID ).
Fields #
| Name | Description |
|---|---|
VmId UnicodeString | |
Time UnicodeString | |
Parameter0 UnicodeString | |
Parameter1 UInt32 |
Event ID 25413: Finished Unassigning VF (VFID: Parameter1) on Nic (Name: Parameter0), time Time s.
#Event ID 33010: Could not find an Ethernet connection resource pool with ID 'Parameter0'
#Description
Could not find an Ethernet connection resource pool with ID 'Parameter0'.
Fields #
| Name | Description |
|---|---|
Parameter0 UnicodeString |
Event ID 33010: Could not find an Ethernet connection resource pool with ID 'Parameter0'.
#Provenance
Where this provider's schema came from, and which Windows build it was observed on. Windows can change a provider's event schema between builds, so use this to judge whether it matches the build you collect from.
ETW provider GUID c29c4fb7-b60e-4fff-9af9-cf21f9b09a34
Defined in VmSynthNic.dll, which carries the event manifest.
Observed on:
- Win11-26200.6584, schema read from the registered manifest, binary version 10.0.26100.1, captured 2026-06-02