Microsoft-WindowsPhone-UfxSynopsys
11 events across 1 channel
| Event | Title | Channel | Sample |
|---|---|---|---|
| 100 | Failed with status Status in file File on line Line. | Unknown | N |
| 101 | READ Offset Value. | Unknown | N |
| 102 | WRITE Offset Value. | Unknown | N |
| 200 | TRANSFER Stage: Endpoint (PhysicalEndpoint), RQ: Request, DMA: Transaction, … | Unknown | N |
| 201 | TRB: Endpoint (PhysicalEndpoint) -- (Index) Word1 Word2 Word3 Word4. | Unknown | N |
| 202 | COMMAND Name: Endpoint (PhysicalEndpoint) -- Command Parameter0 Parameter1 … | Unknown | N |
| 301 | Endpoint Information | Unknown | N |
| 302 | Charger Detection Error | Unknown | N |
| 303 | Failed to determine port type | Unknown | N |
| 304 | Register Information | Unknown | N |
| 305 | Connected Standby: ConnectedStandby, Idle Residency: IdleResidency, Device Power … | Unknown | N |
Event ID 100: Failed with status Status in file File on line Line.
#Description
Failed with status Status in file File on line Line.
Message #
Fields #
| Name | Description |
|---|---|
File AnsiString | |
Line UInt32 | |
Status UInt32 | NTSTATUS reference |
Event ID 101: READ Offset Value.
#Event ID 102: WRITE Offset Value.
#Event ID 200: TRANSFER Stage: Endpoint (PhysicalEndpoint), RQ: Request, DMA: Transaction, BytesReq: BytesRequested, BytesProg: BytesProgrammed, BytesTrans: BytesTransferred, SG: SgProgrammed/SgLength, TRB:TrbPro...
#Description
TRANSFER Stage: Endpoint (PhysicalEndpoint), RQ: Request, DMA: Transaction, BytesReq: BytesRequested, BytesProg: BytesProgrammed, BytesTrans: BytesTransferred, SG: SgProgrammed/SgLength, TRB:TrbProgrammed/TrbLength.
Message #
Fields #
| Name | Description |
|---|---|
Stage AnsiString | |
Endpoint Pointer | |
PhysicalEndpoint UInt32 | |
Request Pointer | |
Transaction Pointer | |
BytesRequested UInt32 | |
BytesProgrammed UInt32 | |
BytesTransferred UInt32 | |
SgProgrammed UInt32 | |
SgLength UInt32 | |
TrbProgrammed UInt32 | |
TrbLength UInt32 |
Event ID 201: TRB: Endpoint (PhysicalEndpoint) -- (Index) Word1 Word2 Word3 Word4.
#Event ID 202: COMMAND Name: Endpoint (PhysicalEndpoint) -- Command Parameter0 Parameter1 Parameter2.
#Event ID 301: Endpoint Information
#Event ID 302: Charger Detection Error
#Event ID 303: Failed to determine port type
#Event ID 304: Register Information
#Description
Register Information.
Message #
Fields #
| Name | Description |
|---|---|
Configuration UInt32 | |
Control UInt32 | |
EnabledEvents UInt32 | |
Status UInt32 | NTSTATUS reference |
Event ID 305: Connected Standby: ConnectedStandby, Idle Residency: IdleResidency, Device Power State: DevicePowerState, Connected: Connected, Port Type: UsbPortType, USB Device State: UsbDeviceState.
#Description
Connected Standby: ConnectedStandby, Idle Residency: IdleResidency, Device Power State: DevicePowerState, Connected: Connected, Port Type: UsbPortType, USB Device State: UsbDeviceState.
Message #
Fields #
| Name | Description |
|---|---|
ConnectedStandby Boolean | |
IdleResidency Boolean | |
DevicePowerState UInt32 | |
Connected Boolean | |
UsbPortType UInt32 | |
UsbDeviceState UInt32 |
Provenance
Where this provider's schema came from, and which Windows build it was observed on. Windows can change a provider's event schema between builds, so use this to judge whether it matches the build you collect from.
ETW provider GUID 49b12c7c-4bd5-4f93-bb75-30fce739600b
Defined in ufxsynopsys.sys, the binary that emits these events.
Observed on:
- WS2022-20348.4893, schema read from the registered manifest, binary version 10.0.20348.1, captured 2026-06-02
- Win11-26200.6584, schema read from the registered manifest, binary version 10.0.26100.1150, captured 2026-06-02