Detection rules › Sigma
ETW Logging Disabled For SCM
Detects changes to the "TracingDisabled" key in order to disable ETW logging for services.exe (SCM)
MITRE ATT&CK coverage
| Tactic | Techniques |
|---|---|
| Persistence | T1112 Modify Registry |
| Defense Impairment | T1112 Modify Registry, T1685 Disable or Modify Tools |
Event coverage
| Provider | Event | Title |
|---|---|---|
| Sysmon | Event ID 13 | RegistryEvent (Value Set) |
Rule body yaml
title: ETW Logging Disabled For SCM
id: 4f281b83-0200-4b34-bf35-d24687ea57c2
status: test
description: Detects changes to the "TracingDisabled" key in order to disable ETW logging for services.exe (SCM)
references:
- http://redplait.blogspot.com/2020/07/whats-wrong-with-etw.html
author: Nasreddine Bencherchali (Nextron Systems)
date: 2022-12-09
modified: 2023-08-17
tags:
- attack.persistence
- attack.defense-impairment
- attack.t1112
- attack.t1685
logsource:
product: windows
category: registry_set
detection:
selection:
TargetObject|endswith: 'Software\Microsoft\Windows NT\CurrentVersion\Tracing\SCM\Regular\TracingDisabled'
Details: 'DWORD (0x00000001)' # Funny (sad) enough, this value is by default 1.
condition: selection
falsepositives:
- Unknown
level: low
Stages and Predicates
Stage 0: condition
selectionStage 1: selection
selection:
TargetObject|endswith: 'Software\Microsoft\Windows NT\CurrentVersion\Tracing\SCM\Regular\TracingDisabled'
Details: 'DWORD (0x00000001)'
Indicators
Each row is a field, operator, and value that the rule matches. The corpus column counts how many other rules in the catalog look for the same combination: high numbers point to widely-used, community-vetted indicators. Blank or 1 shows that the indicator is specific to this rule.
| Field | Kind | Values |
|---|---|---|
Details | eq |
|
TargetObject | ends_with |
|